2011 Nuclear Power Plant Sourcebook: Spent Nuclear Fuel and the Risks of Heatup After the Loss of Water - NRC Reports - Crisis at Japan's TEPCO Fukushima Daiichi Power Plant

Nonfiction, Science & Nature, Science, Physics, General Physics, Social & Cultural Studies, Political Science
Cover of the book 2011 Nuclear Power Plant Sourcebook: Spent Nuclear Fuel and the Risks of Heatup After the Loss of Water - NRC Reports - Crisis at Japan's TEPCO Fukushima Daiichi Power Plant by Progressive Management, Progressive Management
View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart
Author: Progressive Management ISBN: 9781458091994
Publisher: Progressive Management Publication: March 16, 2011
Imprint: Smashwords Edition Language: English
Author: Progressive Management
ISBN: 9781458091994
Publisher: Progressive Management
Publication: March 16, 2011
Imprint: Smashwords Edition
Language: English

The crisis at the TEPCO Fukushima Daiichi Nuclear Power Station in Japan following the great earthquake and tsunami of March 11, 2011 has raised important issues about the safety of spent nuclear fuel rod storage, especially those located at the top of boiling water reactor (BWR) units. At press time, TEPCO is reporting that water levels in the spent nuclear fuel pools located above the reactors in the Number 3 and Number 4 units of the Fukushima Daiichi Power Station are heating up and running low on water. There is extreme concern that the fuel rods in those pools could overheat and possibly release large amounts of radiation. After a brief overview of the handling of spent nuclear fuels, we present two major studies for the Nuclear Regulatory Commission (NRC) which deal with the hazards of reactor spent fuel pools. The first report, by the Sandia Laboratories, specifically addresses the type of situation faced by TEPCO at Fukushima with boiling water reactors (BWR). The second report, by the Brookhaven National Laboratory, characterizes the radiological risks posed by storage of spent reactor fuel at commercial reactors. Finally, we reproduce a report by the GAO about the safety of spent nuclear fuel.

Allen Benjamin and others, writing in the Sandia report, state: "Analysis of spent fuel heatup following a hypothetical accident involving drainage of the storage pool is presented. Computations based upon a new computer code called SFUEL have been performed to assess the effect of decay time, fuel element design, storage rack design, packing density, room ventilation, drainage level, and other variables on the heatup characteristics of the spent fuel and to predict the conditions under which clad failure will occur. It has been found that the likelihood of clad failure due to rupture or melting following a complete drainage is extremely dependent on the storage configuration and the spent fuel decay period, and that the minimum prerequisite decay time to preclude clad failure may vary from less than 10 days for some storage configurations to several years for others."

The report discusses emergency aspects of pool water loss relevant to the Japanese situation. "An alternative way to maintain coolability, at least on a temporary basis, would be to provide an emergency water spray of sufficient intensity to remove the decay heat by its latent heat of vaporization. The water supply could be available from onsite hydrants, from onsite storage tanks, from remote portable storage tanks, or, preferably, from a combination of onsite and remote sources in order to reduce the risk of unavailability. Facility personnel would presumably be available to set up fire hoses and initiate the spray in the event of a complete power failure, and the spray would be continued until the source of the leak could be repaired."

The abstract for the BNL report reads: "This investigation provides an assessment of the likelihood and consequences of a severe accident in a spent fuel storage pool - the complete draining of the pool. Potential mechanisms and conditions for failure of the spent fuel, and the subsequent release of the fission products, are identified. Two older PWR and BWR spent fuel storage pool designs are considered based on a preliminary screening study which tried to identify vulnerabilities. Internal and external events and accidents are assessed. Conditions which could lead to failure of the spent fuel Zircaloy cladding as a result of cladding rupture or as a result of a self-sustaining oxidation reaction are presented. Propagation of a cladding fire to older stored fuel assemblies is evaluated. The uncertainties in the risk estimate are large, and areas where additional evaluations are needed to reduce uncertainty are identified."

View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart

The crisis at the TEPCO Fukushima Daiichi Nuclear Power Station in Japan following the great earthquake and tsunami of March 11, 2011 has raised important issues about the safety of spent nuclear fuel rod storage, especially those located at the top of boiling water reactor (BWR) units. At press time, TEPCO is reporting that water levels in the spent nuclear fuel pools located above the reactors in the Number 3 and Number 4 units of the Fukushima Daiichi Power Station are heating up and running low on water. There is extreme concern that the fuel rods in those pools could overheat and possibly release large amounts of radiation. After a brief overview of the handling of spent nuclear fuels, we present two major studies for the Nuclear Regulatory Commission (NRC) which deal with the hazards of reactor spent fuel pools. The first report, by the Sandia Laboratories, specifically addresses the type of situation faced by TEPCO at Fukushima with boiling water reactors (BWR). The second report, by the Brookhaven National Laboratory, characterizes the radiological risks posed by storage of spent reactor fuel at commercial reactors. Finally, we reproduce a report by the GAO about the safety of spent nuclear fuel.

Allen Benjamin and others, writing in the Sandia report, state: "Analysis of spent fuel heatup following a hypothetical accident involving drainage of the storage pool is presented. Computations based upon a new computer code called SFUEL have been performed to assess the effect of decay time, fuel element design, storage rack design, packing density, room ventilation, drainage level, and other variables on the heatup characteristics of the spent fuel and to predict the conditions under which clad failure will occur. It has been found that the likelihood of clad failure due to rupture or melting following a complete drainage is extremely dependent on the storage configuration and the spent fuel decay period, and that the minimum prerequisite decay time to preclude clad failure may vary from less than 10 days for some storage configurations to several years for others."

The report discusses emergency aspects of pool water loss relevant to the Japanese situation. "An alternative way to maintain coolability, at least on a temporary basis, would be to provide an emergency water spray of sufficient intensity to remove the decay heat by its latent heat of vaporization. The water supply could be available from onsite hydrants, from onsite storage tanks, from remote portable storage tanks, or, preferably, from a combination of onsite and remote sources in order to reduce the risk of unavailability. Facility personnel would presumably be available to set up fire hoses and initiate the spray in the event of a complete power failure, and the spray would be continued until the source of the leak could be repaired."

The abstract for the BNL report reads: "This investigation provides an assessment of the likelihood and consequences of a severe accident in a spent fuel storage pool - the complete draining of the pool. Potential mechanisms and conditions for failure of the spent fuel, and the subsequent release of the fission products, are identified. Two older PWR and BWR spent fuel storage pool designs are considered based on a preliminary screening study which tried to identify vulnerabilities. Internal and external events and accidents are assessed. Conditions which could lead to failure of the spent fuel Zircaloy cladding as a result of cladding rupture or as a result of a self-sustaining oxidation reaction are presented. Propagation of a cladding fire to older stored fuel assemblies is evaluated. The uncertainties in the risk estimate are large, and areas where additional evaluations are needed to reduce uncertainty are identified."

More books from Progressive Management

Cover of the book Air Policing: Case Studies of Employment and Evolution of British Air Policing from 1919 to 1934, Inverted Blockade, Third Afghan War, Somaliland, Mesopotamia, Aden, Comparison to Iraq COIN by Progressive Management
Cover of the book Dangerous Illicit Drug Alerts: Synthetic Cathinones (Bath Salts), Mephedrone, Synthetic Cannabinoids, Purple Drank, Synthetic Hallucinogen 2C-E, Oxymorphone Abuse, Opium Tea, Salvia Divinorum by Progressive Management
Cover of the book 2010 Planning Guidance for Response to a Nuclear Detonation: Federal Guidance for a Nuclear Bomb Attack on an American City, Effects, Fallout, Shelter, Medical Care, Decontamination by Progressive Management
Cover of the book Military Justice in Combat Zones: Iraq and Afghanistan War Case Summaries of U.S. Marine Corps Haditha; Army Maywand District Killings, Army Mahmoudiyah Iraq, Investigations by Progressive Management
Cover of the book The Innate Insurgent Advantage: Can Training and Planning Bridge the Gap? Iraqi Freedom and Enduring Freedom, Afghanistan, Terrorism, Casualties and Chaos, COIN Counterinsurgency, MRAP Vehicles, Kits by Progressive Management
Cover of the book Hunting the Ghost Gun: An Analysis of the U.S. Army Infantry Rifle - On the Battlefields, Ammunition and Small Arms Weapons, Garand, M14, M16, M4, Vietnam, Persian Gulf, Afghanistan, Performance by Progressive Management
Cover of the book 21st Century NBC WMD CBRN Weapons and Terrorism: Guidelines for Mass Casualty Decontamination During a HAZMAT/Weapon of Mass Destruction Incident (Two Volumes) by Progressive Management
Cover of the book Safe School Initiative, Prevention of School Attacks, Columbine High School Report on Emergency Response, Presidential Report on the Virginia Tech Tragedy, School Shooter Threat Assessment by Progressive Management
Cover of the book Hybrid Warfare: Israel-Hezbollah War, World War II Eastern Front, American Experience in Vietnam, Operation Iraqi Freedom, Operational Approaches to Hybrid Warfare by Progressive Management
Cover of the book 21st Century Understanding Cancer Toolkit: Coping with Advanced Cancer - Metastatic Cancer, Caregiver Support, Palliative Care and Hospice, Advance Directives, End-of-Life Care, Pain Control, Grief by Progressive Management
Cover of the book The Columbia River System: Inside Story (Second Edition) - Dams, Water Projects, Hydrology, Flood Control, Fish and Wildlife, Power, Navigation, Irrigation, Snake River, Kootenai, Willamette by Progressive Management
Cover of the book 2018 Commerce Department Report on the Effect of Imports of Steel on the National Security: Analysis of Options for Proposed Global Quota or Tariff to Protect the American Steel Industry by Progressive Management
Cover of the book Joint Theater Trauma System Clinical Practice Guidelines - Practical Emergency Information for Critical Trauma Care, Burns, Compartment Syndrome, Wounds, Head and Spine (Emergency War Surgery Series) by Progressive Management
Cover of the book Nuclear Navy 1946-1962: History of Navy's Nuclear Propulsion Program - Hyman Rickover, Nimitz, Nautilus, AEC, Nuclear Submarines, Reactors, Atoms for Peace, Thresher, Polaris Missile by Progressive Management
Cover of the book Within Our Reach: A National Strategy to Eliminate Child Abuse and Neglect Fatalities - 2016 Report of the Commission to Eliminate Child Abuse and Neglect Fatalities, Special Populations, Support by Progressive Management
We use our own "cookies" and third party cookies to improve services and to see statistical information. By using this website, you agree to our Privacy Policy