2011 Nuclear Power Plant Sourcebook: Spent Nuclear Fuel and the Risks of Heatup After the Loss of Water - NRC Reports - Crisis at Japan's TEPCO Fukushima Daiichi Power Plant

Nonfiction, Science & Nature, Science, Physics, General Physics, Social & Cultural Studies, Political Science
Cover of the book 2011 Nuclear Power Plant Sourcebook: Spent Nuclear Fuel and the Risks of Heatup After the Loss of Water - NRC Reports - Crisis at Japan's TEPCO Fukushima Daiichi Power Plant by Progressive Management, Progressive Management
View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart
Author: Progressive Management ISBN: 9781458091994
Publisher: Progressive Management Publication: March 16, 2011
Imprint: Smashwords Edition Language: English
Author: Progressive Management
ISBN: 9781458091994
Publisher: Progressive Management
Publication: March 16, 2011
Imprint: Smashwords Edition
Language: English

The crisis at the TEPCO Fukushima Daiichi Nuclear Power Station in Japan following the great earthquake and tsunami of March 11, 2011 has raised important issues about the safety of spent nuclear fuel rod storage, especially those located at the top of boiling water reactor (BWR) units. At press time, TEPCO is reporting that water levels in the spent nuclear fuel pools located above the reactors in the Number 3 and Number 4 units of the Fukushima Daiichi Power Station are heating up and running low on water. There is extreme concern that the fuel rods in those pools could overheat and possibly release large amounts of radiation. After a brief overview of the handling of spent nuclear fuels, we present two major studies for the Nuclear Regulatory Commission (NRC) which deal with the hazards of reactor spent fuel pools. The first report, by the Sandia Laboratories, specifically addresses the type of situation faced by TEPCO at Fukushima with boiling water reactors (BWR). The second report, by the Brookhaven National Laboratory, characterizes the radiological risks posed by storage of spent reactor fuel at commercial reactors. Finally, we reproduce a report by the GAO about the safety of spent nuclear fuel.

Allen Benjamin and others, writing in the Sandia report, state: "Analysis of spent fuel heatup following a hypothetical accident involving drainage of the storage pool is presented. Computations based upon a new computer code called SFUEL have been performed to assess the effect of decay time, fuel element design, storage rack design, packing density, room ventilation, drainage level, and other variables on the heatup characteristics of the spent fuel and to predict the conditions under which clad failure will occur. It has been found that the likelihood of clad failure due to rupture or melting following a complete drainage is extremely dependent on the storage configuration and the spent fuel decay period, and that the minimum prerequisite decay time to preclude clad failure may vary from less than 10 days for some storage configurations to several years for others."

The report discusses emergency aspects of pool water loss relevant to the Japanese situation. "An alternative way to maintain coolability, at least on a temporary basis, would be to provide an emergency water spray of sufficient intensity to remove the decay heat by its latent heat of vaporization. The water supply could be available from onsite hydrants, from onsite storage tanks, from remote portable storage tanks, or, preferably, from a combination of onsite and remote sources in order to reduce the risk of unavailability. Facility personnel would presumably be available to set up fire hoses and initiate the spray in the event of a complete power failure, and the spray would be continued until the source of the leak could be repaired."

The abstract for the BNL report reads: "This investigation provides an assessment of the likelihood and consequences of a severe accident in a spent fuel storage pool - the complete draining of the pool. Potential mechanisms and conditions for failure of the spent fuel, and the subsequent release of the fission products, are identified. Two older PWR and BWR spent fuel storage pool designs are considered based on a preliminary screening study which tried to identify vulnerabilities. Internal and external events and accidents are assessed. Conditions which could lead to failure of the spent fuel Zircaloy cladding as a result of cladding rupture or as a result of a self-sustaining oxidation reaction are presented. Propagation of a cladding fire to older stored fuel assemblies is evaluated. The uncertainties in the risk estimate are large, and areas where additional evaluations are needed to reduce uncertainty are identified."

View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart

The crisis at the TEPCO Fukushima Daiichi Nuclear Power Station in Japan following the great earthquake and tsunami of March 11, 2011 has raised important issues about the safety of spent nuclear fuel rod storage, especially those located at the top of boiling water reactor (BWR) units. At press time, TEPCO is reporting that water levels in the spent nuclear fuel pools located above the reactors in the Number 3 and Number 4 units of the Fukushima Daiichi Power Station are heating up and running low on water. There is extreme concern that the fuel rods in those pools could overheat and possibly release large amounts of radiation. After a brief overview of the handling of spent nuclear fuels, we present two major studies for the Nuclear Regulatory Commission (NRC) which deal with the hazards of reactor spent fuel pools. The first report, by the Sandia Laboratories, specifically addresses the type of situation faced by TEPCO at Fukushima with boiling water reactors (BWR). The second report, by the Brookhaven National Laboratory, characterizes the radiological risks posed by storage of spent reactor fuel at commercial reactors. Finally, we reproduce a report by the GAO about the safety of spent nuclear fuel.

Allen Benjamin and others, writing in the Sandia report, state: "Analysis of spent fuel heatup following a hypothetical accident involving drainage of the storage pool is presented. Computations based upon a new computer code called SFUEL have been performed to assess the effect of decay time, fuel element design, storage rack design, packing density, room ventilation, drainage level, and other variables on the heatup characteristics of the spent fuel and to predict the conditions under which clad failure will occur. It has been found that the likelihood of clad failure due to rupture or melting following a complete drainage is extremely dependent on the storage configuration and the spent fuel decay period, and that the minimum prerequisite decay time to preclude clad failure may vary from less than 10 days for some storage configurations to several years for others."

The report discusses emergency aspects of pool water loss relevant to the Japanese situation. "An alternative way to maintain coolability, at least on a temporary basis, would be to provide an emergency water spray of sufficient intensity to remove the decay heat by its latent heat of vaporization. The water supply could be available from onsite hydrants, from onsite storage tanks, from remote portable storage tanks, or, preferably, from a combination of onsite and remote sources in order to reduce the risk of unavailability. Facility personnel would presumably be available to set up fire hoses and initiate the spray in the event of a complete power failure, and the spray would be continued until the source of the leak could be repaired."

The abstract for the BNL report reads: "This investigation provides an assessment of the likelihood and consequences of a severe accident in a spent fuel storage pool - the complete draining of the pool. Potential mechanisms and conditions for failure of the spent fuel, and the subsequent release of the fission products, are identified. Two older PWR and BWR spent fuel storage pool designs are considered based on a preliminary screening study which tried to identify vulnerabilities. Internal and external events and accidents are assessed. Conditions which could lead to failure of the spent fuel Zircaloy cladding as a result of cladding rupture or as a result of a self-sustaining oxidation reaction are presented. Propagation of a cladding fire to older stored fuel assemblies is evaluated. The uncertainties in the risk estimate are large, and areas where additional evaluations are needed to reduce uncertainty are identified."

More books from Progressive Management

Cover of the book 2011 Domestic Operational Law Handbook for Judge Advocates - WMD, CBRNE, Civil Disturbance, National Incident Management System (NIMS), Posse Comitatus, Special Events, Rules for Use of Forces by Progressive Management
Cover of the book Personnel Replacement Operations During Operations Desert Storm and Desert Shield: Interviews to Assess Theater Replacements in the First Gulf War in Iraq, Doctrinal Publications and Echelon by Progressive Management
Cover of the book 21st Century U.S. Military Manuals: Operations Field Manual - FM 3-0 (Value-Added Professional Format Series) by Progressive Management
Cover of the book T-6A TEXAN II Systems Engineering Case Study: Derivative of PC-9 Pilatus Aircraft - JPATS Program, Training System, Hawker Beechcraft History by Progressive Management
Cover of the book The Assassin's Dagger: An Exploration of the German Judiciary in the Third Reich - Upholding Nazi Laws for Adolf Hitler, Legalization and Enablement of Holocaust, Murder of Jews, Nuremberg Tribunals by Progressive Management
Cover of the book Seize the High Ground: The Army in Space and Missile Defense - NIKE-ZEUS, Safeguard, Ballistic Missile Defense, Sentry, Strategic Defense Initiative, Anti-satellite, Laser, Space Shuttle by Progressive Management
Cover of the book The Army's Role in the Air/Sea Battle Concept: A World War II Pacific Theater Case Study - Role of Logistics Bases, Guadalcanal, Saipan, Okinawa, Admiral Nimitz, Solomons, Philippines by Progressive Management
Cover of the book People's Liberation Army After Next: China's PLA, Air Force Aircraft, Ballistic and Cruise Missiles, EMP, DF-11, DF-15, Silkworm, Fighter Aircraft, Taiwan, Advanced Technology, Military Space by Progressive Management
Cover of the book 21st Century U.S. Military Manuals: Army Handbook for Self-Development - Strengths, Weaknesses, Roles, Responsibilities, Learning and Motivation, Roadblocks, Milestones (Professional Format Series) by Progressive Management
Cover of the book 21st Century FEMA Study Course: Livestock in Disasters (IS-111) - For Farmers, Extension Agents - Cattle, Pigs, Poultry, Floods, Storms by Progressive Management
Cover of the book Liberating Kuwait: U.S. Marines in the Gulf War, 1990-1991, Iraq's Saddam Hussein and the Invasion of Kuwait, Defending Saudi Arabia, Air War, Scuds, al-Khafji, Harriers Afloat, Fratricide Issues by Progressive Management
Cover of the book V-22 Osprey Guidebook: Systems Descriptions, Mission Snapshots from Afghanistan, Iraq, Libya, Haiti, Tactical, Operational, and Strategic Reach, Current and Future Capabilities, Suppliers by Progressive Management
Cover of the book NASA Human Spaceflight Astronaut Health Research for Exploration and Manned Mars Missions, Risk Report WSN-07, Human Computer Interaction, Task Design, Injury from Dynamic Loads, Food System Illness by Progressive Management
Cover of the book 21st Century Complete Guide to Ricin Terrorism and Poisoning with the Defense Against Toxin Weapons Army Manual (Biological Warfare and Weapons) by Progressive Management
Cover of the book Battlefield Medical Network: Biosensors in a Tactical Environment - Remote Health Monitoring, Telemetry, Traumatic Brain Injury (TBI), Bench and Field Experiments, Data Analysis and Findings by Progressive Management
We use our own "cookies" and third party cookies to improve services and to see statistical information. By using this website, you agree to our Privacy Policy