The AOjASIF* dynamic hip screw (DRS) has been designed primarily to stabilize trochanteric fractures of the hip. Selected fractures of the femoral neck and some subtrochanteric fractures are further indications for the DRS [40, 46]. The dynam­ ic condylar screw (DCS) has been developed for fractures of the distal femur and is now being tested clinically. The DRS and DCS are carefully coordinated with the preexisting ASIF standard sets of equipment for internal fixation of fractures. The concept of a sliding screw for trochanteric fractures is not new. The first author describing such an implant was Schumpelick [44]; he gives credit to Pohl [22], who was primarily a manufacturer working for Gerhardt Kiinscher. Re described the possibility of impaction at the fracture site with a sliding device. In the United States Clawson [7, 8] introduced the hip screw and found it to be extremely beneficial in trochanteric fractures. At approximately the same time, Massie [31, 32] and Pugh [39] designed the sliding-type flange nails, which offer similar intramedullary splinting with the possibility of fracture impaction. The following chapters describe the concept and design features of the DRS, as well as the details of the surgical technique. The application of the DRS for different types of fractures is illustrated with clinical examples. The results of 268 cases of trochanteric fractures treated with the DRS are presented and compared with results using the angled blade plate and Ender's nails. Finally, some laboratory tests are described.

View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart

The AOjASIF* dynamic hip screw (DRS) has been designed primarily to stabilize trochanteric fractures of the hip. Selected fractures of the femoral neck and some subtrochanteric fractures are further indications for the DRS [40, 46]. The dynam­ ic condylar screw (DCS) has been developed for fractures of the distal femur and is now being tested clinically. The DRS and DCS are carefully coordinated with the preexisting ASIF standard sets of equipment for internal fixation of fractures. The concept of a sliding screw for trochanteric fractures is not new. The first author describing such an implant was Schumpelick [44]; he gives credit to Pohl [22], who was primarily a manufacturer working for Gerhardt Kiinscher. Re described the possibility of impaction at the fracture site with a sliding device. In the United States Clawson [7, 8] introduced the hip screw and found it to be extremely beneficial in trochanteric fractures. At approximately the same time, Massie [31, 32] and Pugh [39] designed the sliding-type flange nails, which offer similar intramedullary splinting with the possibility of fracture impaction. The following chapters describe the concept and design features of the DRS, as well as the details of the surgical technique. The application of the DRS for different types of fractures is illustrated with clinical examples. The results of 268 cases of trochanteric fractures treated with the DRS are presented and compared with results using the angled blade plate and Ender's nails. Finally, some laboratory tests are described.

More books from Springer Berlin Heidelberg

Cover of the book Mathematical Models for Evacuation Planning in Urban Areas by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Molecular Conformation and Organic Photochemistry by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Bones and Joints by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Neuroinflammation in Stroke by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Computed Tomography of the Cranial Skeleton (Face and Skull) by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Cardio-Respiratory Control in Vertebrates by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Human Fungal Pathogens by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Skull Traction and Cervical Cord Injury by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Geology of Hungary by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Climate Change, Energy, Sustainability and Pavements by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Essenz der Führung by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Gene Network Inference by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Comprehensive and Clinical Anatomy of the Middle Ear by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Advanced Field-Solver Techniques for RC Extraction of Integrated Circuits by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
Cover of the book Transactions on Petri Nets and Other Models of Concurrency XII by P. Regazzoni, R. Winquist, M. Allgöwer, T. Rüedi
We use our own "cookies" and third party cookies to improve services and to see statistical information. By using this website, you agree to our Privacy Policy